Search results for "Pulse repetition frequency"
showing 6 items of 6 documents
Effect of changing pulse rate on profile parameters of perceptual thresholds and loudness comfort levels and relation to ECAP thresholds in recipient…
2010
Abstract: The Nucleus CI24RE Freedom device offers higher stimulation rates and lower noise levels in action potential measurements (ECAPs) than previous devices. A study including ten European implant teams showed that the effect of changes in rate from 250 to 3500 pulses per second on tilt and curvature of the T and C profiles is insignificant. When changing rate one may change the levels at all electrodes by the same amount. Using an automated procedure ECAPs could be measured quickly and reliably at a noise level of only 1 μV. However, this did not result in improved correlations between the tilt and curvature parameters of the ECAP profiles and those of the T and C profiles. Average C …
Speech perception performance as a function of stimulus pulse rate and processing strategy preference for the Cochlear™ Nucleus®CI24RE device: Relati…
2010
Current cochlear implants can operate at high pulse rates. The effect of increasing pulse rate on speech performance is not yet clear. Habituation to low rates may affect the outcome. This paper presents the results of three subsequent studies using different experimental paradigms, applying the Nucleus CI24RE device, and conducted by ten European implant teams. Pulse rate per channel varied from 500 to 3500 pulses per second with ACE and from 1200 to 3500 pps with CIS strategy. The results showed that the first rate presented had little effect on the finally preferred rate. Lower rates were preferred. The effect of pulse rate on word scores of post-linguistic implantees was small; high rat…
Surface plasmon assisted thermal coupling of multiple photon energies
2006
A novel optical effect can be observed in a thin gold foil due to the excitation of surface plasmons which permits a form of all-optical modulation at low pulse rates. Modulated excitation of surface plasmons by infrared photons is shown to couple to several beams at visible-photon energies. The coupling is manifested by the observation of the visible photons being pulsed by the action of the infrared pulses, and by the far field diffraction of the visible beams into concentric rings. When each visible beam also excites surface plasmons, then a quadratic dependence of the visible photon power upon the infrared incident power is measured. The decay of surface plasmons is implicated as the pr…
A powerful thyristor modulator for a microtron
1980
Abstract The circuit of a powerful modulator is illustrated and a detailed description is given of the modulator construction and in particular of the components employed. The main parameters are: length of shaped pulse 2 μs; amplitude of the output voltage 30 kV; pulse repetition frequency 50–200 Hz. The compactness of this device, its comparatively low cost and its good performance, as illustrated in the attached photographs, make it suitable for use in accelerator engineering (microtron).
Sub-200-kHz single soliton generation in a long ring Er-fiber laser with strict polarization control by using twisted fiber
2020
Abstract In the present work we demonstrate a novel single-soliton ultra-low pulse repetition frequency passively mode-locked erbium-doped fiber laser. We mitigate the residual linear birefringence of fiber by fiber twist to achieve a strict control of polarization. For mode-locking the nonlinear polarization rotation (NPR) was used. Special technique was applied to reduce the overdriving of NPR that allows the generation of single soliton in ultra-long cavity. The strict control of polarization yields a stable relation between the polarization state of the pulses propagating in the cavity and the regimes of generation. A 192.12-kHz train of soliton pulses was obtained with pulse duration o…
Assessment of a Modified Acoustic Lens for Electromagnetic Shock Wave Lithotripters in a Swine Model
2013
The acoustic lens of the Modularis electromagnetic shock wave lithotripter (Siemens, Malvern, Pennsylvania) was modified to produce a pressure waveform and focal zone more closely resembling that of the original HM3 device (Dornier Medtech, Wessling, Germany). We assessed the newly designed acoustic lens in vivo in an animal model.Stone fragmentation and tissue injury produced by the original and modified lenses of the Modularis lithotripter were evaluated in a swine model under equivalent acoustic pulse energy (about 45 mJ) at 1 Hz pulse repetition frequency. Stone fragmentation was determined by the weight percent of stone fragments less than 2 mm. To assess tissue injury, shock wave trea…